Not sure which gland fits your cable?

Send CME the measured outer diameter of your cable, the body material you need (plastic, nickel-plated brass, or stainless steel), and the required IP class. We'll match it to the right BIMED variant and put together a B2B quote.

Send an RFQ →

Why thread size alone isn't enough

The thread size (M12, M16, M20...) determines which hole the gland screws into — it doesn't tell you what cable diameter it will actually clamp. For a given thread size, manufacturers typically offer several variants with different clamping-range inserts, matched to different cable diameters. M20×1.5 in BIMED's range, for example, comes in five different clamping-range variants — from 5.0–9.0 mm up to 10.0–14.0 mm. Specifying thread size alone, without checking the available clamping ranges, is the most common reason a gland order comes back wrong.

Clamping ranges from BIMED's catalogue

The figures below come from BIMED's official 2024 product catalogue for standard metric-thread cable glands. For each thread size we show the combined clamping range across all available variants — the actual number of sub-ranges within one thread size is usually more than one.

ThreadRange — plastic (mm)Range — brass (mm)
M12×1.52.0–6.52.0–6.5
M16×1.52.0–10.02.0–10.0
M20×1.55.0–14.05.0–14.0
M25×1.59.0–18.07.0–18.0
M32×1.511.0–25.09.0–25.0
M40×1.516.0–32.012.0–32.0
M50×1.525.0–38.020.0–44.0
M63×1.529.0–44.029.0–53.0
M75×2.048.0–55.0—

The combined range spans 1 to 5 clamping sub-variants per thread size, depending on the size — each with its own narrower range. We confirm the exact variant for your cable diameter individually; figures are from BIMED's manufacturer catalogue, April 2024.

How to measure your cable's diameter correctly

  1. Measure the actual outer diameter of the cable jacket with calipers — not the nominal value from the cable's datasheet, which can vary ±0.3–0.5 mm batch to batch.
  2. Take the measurement at several points and angles — cable cross-sections are rarely a perfect circle (ovality), especially with multi-core cables or PVC jackets.
  3. If the cable has an additional layer (braid, armor, oversheath), determine which layer the gland actually needs to seal against — it may not be the outermost one.
  4. Record both a minimum and maximum measured value, not just one figure — that's what determines whether the cable falls within a published clamping range.
Common mistake

Choosing a gland where the cable diameter lands exactly at the edge of the clamping range (minimum or maximum) instead of nearer the middle. The clamping insert is designed to seal effectively mid-range — at the edge you risk either insufficient compression (no seal) or excessive compression on a small contact area, which over time causes permanent deformation of the cable jacket (the same "cold flow" mechanism described in our article on EV charging station cable glands). If your diameter sits close to a boundary, check the neighboring sub-variant for that thread — a different insert for the same thread size often covers it closer to the middle of its range.

What CME carries today

CME distributes BIMED standard glands with metric threads M12–M75 in plastic (polyamide) and nickel-plated brass, plus a stainless-steel line (clamping ranges per the manufacturer's separate table). Both plastic and brass versions are rated IP68 (5 bar, 30 min) and IP66.

The ranges above apply to standard glands for non-armoured cable. For armoured cable, EMC applications, hazardous areas, or EV charging, separate series with different clamping ranges are available — ask CME for the right series for your application.

BIMED standard cable glands, nickel-plated brass
BIMED standard cable glands, nickel-plated brass — distributed by CME Sp. z o.o.

What to send with your RFQ

  1. The measured outer diameter of your cable (min–max, from several measurements), not just a catalogue value.
  2. Preferred body material: plastic, nickel-plated brass, or stainless steel.
  3. The required thread size (if known) or the mounting hole diameter in the enclosure.
  4. Target IP class, temperature range, and any chemical exposure.
  5. Cable type: non-armoured, armoured, or shielded — and the planned quantity.

Frequently asked questions

Do I measure cable diameter over the conductor insulation or the outer jacket?

Over the actual outer jacket of the cable — that's the surface the gland seals and clamps against.

What if my cable diameter falls between two standard clamping ranges?

Don't force the nearest range. Check whether another sub-variant of the same thread covers your diameter closer to the middle of its range, or consider a reducing seal. CME can help pick the right option based on your measured diameter.

Is the gland's thread size the same as the mounting hole diameter in the enclosure?

Not always directly — it depends on enclosure wall thickness and the mounting method. Please confirm the mounting hole dimension together with your inquiry.

B2B inquiry — cable glands Tell us the measured cable diameter, material, quantity and technical requirements — we'll follow up on available configurations and pricing.
Send an inquiry →

See also the full CME cable gland category.