Sourcing glands for an EV project?

Send CME your cable outside diameter, thread size, operating conditions and expected quantity. We can help identify a suitable variant and prepare a B2B quotation.

Request a quotation →

The problem: the "cold flow" effect in EV charging cables

Cables at EV charging stations work under different conditions than typical industrial cables. They stay permanently connected to the charger, need to maintain IP protection, and have to withstand the heat generated by high charging power — and that heat makes the cable's outer diameter expand and contract as it cycles through temperature changes.

Standard cable glands — lamella-structured or compression designs — clamp the cable over a small contact area. To reach the clamping force they need, manufacturers recommend a high torque value for the cap. On EV cables, that produces permanent deformation of the cable jacket at the clamping point, a phenomenon known as "cold flow." Combined with the cable's own diameter changes under heat, the gland loses its seal, and water can reach the charging connector.

What the standards actually require

Requirements for EV charger components vary by region and by charger manufacturer, but European EV charger manufacturers generally require cable glands to comply with IEC 62196-1, IEC 62196-3, and UL2251.

IEC 62196-1 defines a cable anchorage pull test: the cable is pulled 100 times (no jerks, each pull lasting 1 second), then subjected to a torque for 1 minute — the values depend on the connector's rated current.

Rated currentPulling forceTorqueMax. displacement
5–20 A160 N0.6 Nm2 mm
125 A240 N1.5 Nm2 mm
250 A500 N2.3 Nm2 mm
600–630 A600 N11.0 Nm5 mm
800 A600 N11.0 Nm5 mm

IEC 62196-3 (clause 25.301) adds a separate strain-relief test: a single 750 N pull held for one minute, then a torque per the IEC 62196-1:2022 table.

For comparison, standard cable glands for non-armoured cables, tested for strain relief to EN 62444, reach the following values — depending on cable diameter and seal type:

Cable diameterType AType B
>31–43 mm90 N350 N
>43–55 mm100 N400 N
The short version Even the highest strain-relief figure for standard glands under EN 62444 (400 N, type B) sits well below the Conical Cage's test result (1,500 N). On higher-current connectors, where IEC 62196 requires strain relief in the hundreds of newtons, a standard gland's margin can be very thin — regardless of its stated IP rating.

The solution: the Conical Cage cable gland

The Conical Cage Cable Gland from BIMED — distributed by CME — was designed specifically for this problem. Instead of clamping the cable over a small area, its seal wraps the cable jacket over a much larger contact surface. Since pressure is force divided by area, the same clamping force spread over a larger surface means far lower stress on the cable jacket. According to BIMED, this design eliminates the cold-flow effect and keeps the seal intact regardless of how the cable's diameter shifts with heat.

Tested to IEC 62196-1 and IEC 62196-3, the Conical Cage gland passed the strain-relief test at 1,500 N — several times the value required even for the highest-rated connectors (600 N per the IEC 62196-1 table), and well above what standard glands achieve under EN 62444.

BIMED Conical Cage cable gland
Conical Cage cable gland — BIMED, distributed by CME Sp. z o.o.

Technical specifications

Thread sizeCable clamping rangeStrain-relief test result
M50 × 1.538–42 mm1500 N
M6341–48 mm1500 N

The 1,500 N figure comes from the IEC 62196-1/-3 strain-relief test for EV applications. BIMED's general product documentation for the same gland lists cable retention up to 1,000 N — a separate test methodology; both figures are manufacturer-published.

The design is also available in an M40 size — please confirm the exact clamping range for that size directly with CME, along with current availability of each size (M50 is currently in serial production at the manufacturer).

Materials: body and cap — nickel-plated brass or stainless steel; clamping insert — PA6 polyamide; seal and O-ring — chloroprene rubber (CR).

All figures are taken from manufacturer (BIMED) documentation. If your specification requires an independently verified test report, contact CME — we can share the available documentation.

BIMED product presentation (PDF)

See the Conical Cage gland in action in the video on our homepage, and browse the full range of EV cable glands below.

What to send with your RFQ

  1. The cable's outside diameter and tolerance, ideally from its datasheet.
  2. Required entry thread, enclosure wall thickness, and installation arrangement.
  3. Target IP rating, temperature range, outdoor exposure, and relevant chemicals.
  4. Mechanical requirements, including expected loads and strain relief.
  5. Expected order quantity, schedule, and documentation requirements.

Frequently asked questions

Does IP68 automatically mean a gland is suitable for an EV charger?

No. An IP rating addresses defined ingress-protection test conditions; it doesn't replace assessment of cable retention, temperature, materials or finished-equipment requirements.

Must every EV charging cable gland comply with IEC 62196?

Don't assume a connector standard applies directly to every separately supplied cable gland. The relevant requirements depend on the component's function, the design of the charging equipment, and the project specification — CME can help you work this out.

How do I select the right BIMED variant?

Start with cable diameter and thread size, then review materials, sealing arrangement and environmental limits. CME can help you request confirmation of the appropriate manufacturer part number.

B2B cable-gland enquiry Send your cable diameter, thread, quantity and engineering requirements — we'll reply on available configurations and pricing.
Request a quote →

Explore CME's full cable-gland product category.