Send CME the operating environment (spray, immersion, pressure washdown), the connector type/pin count/current you need, and the quantity. We'll help confirm the right IP class and put together a B2B quote.
Send an RFQ →Two digits, two completely different tests
An IP rating under IEC 60529 is two digits describing two independent tests: the first digit (0–6) covers protection against solids and dust, the second (0–8) covers protection against water. Each combination is its own test with its own parameters — a higher second digit doesn't automatically mean "more protection in every scenario," just a different test scenario.
IP69K is not part of IEC 60529. It comes from ISO 20653 (derived from the German standard DIN 40050-9), developed for vehicles and machinery exposed to high-pressure washdown. A connector can be IP69K without being IP68 — and vice versa — because these are two separate tests checking different physical phenomena.
Dust: IP5X and IP6X — same test, different pass criterion
Both dust classes are tested in the same chamber with circulating talcum powder (particle size roughly 50 µm, with vacuum applied to enclosures that have internal cavities). The difference is in what counts as a pass: IP5X permits limited dust ingress as long as it doesn't interfere with operation or safety, while IP6X requires zero visible dust inside the enclosure.
| Class | Test duration | Pass criterion |
|---|---|---|
| IP5X | Talc-dust chamber | Limited dust ingress permitted |
| IP6X | At least 8 hours, ~2 kPa vacuum | Zero visible dust — fully dust-tight |
Most industrial waterproof connectors — including the ones CME carries — are tested to IP6X rather than IP5X, so in practice the differences you'll run into are mostly on the water side (the second digit).
IP65 — a water jet, not immersion
IP65 = IP6X (dust-tight) + IPX5. Water test: a 6.3 mm nozzle, 12.5 L/min flow, roughly 30 kPa pressure, from 3 m away, for at least 1 minute per m² of enclosure surface (3-minute minimum overall). The connector must withstand water sprayed from any direction — but the test never involves immersion.
Typical use: outdoor installations exposed to rain and splashing, with no risk of flooding or submersion.
IP67 — accidental, brief immersion
IP67 = IP6X + IPX7. Water test: immersion to a depth of at least 1 m (measured to the bottom of the enclosure, with its top surface at least 0.15 m below the water line) for 30 minutes.
Typical use: connectors exposed to occasional flooding — puddles, brief submersion during heavy rain — but not designed to sit permanently underwater.
IP68 — immersion, but on the manufacturer's terms
IP68 = IP6X + IPX8. This is the most commonly misunderstood rating: IEC 60529 doesn't specify one fixed depth or duration for IPX8 — the standard requires the manufacturer (and, depending on the edition, the user) to agree on and publish the actual test conditions used, which must be more severe than IPX7.
Two products both labeled "IP68" can have been tested at completely different depths and durations — one manufacturer might publish 1.5 m / 30 minutes, another 3 m / 24 hours. The "IP68" label alone doesn't tell you which. Always check the manufacturer's datasheet for the actual immersion test parameters before assuming a product will survive your operating conditions.
IP69K — high-pressure, high-temperature washdown
IP69K describes resistance to high-pressure, high-temperature water jets — the kind of washdown used in industrial cleaning, food and beverage lines, and agricultural or utility vehicles. It's a completely different test from immersion:
| Parameter | Value (ISO 20653 / DIN 40050-9) |
|---|---|
| Water pressure | 80–100 bar |
| Water temperature | 80°C ± 5°C |
| Flow rate | 14–16 L/min |
| Nozzle distance | 100–150 mm |
| Spray angles | 0°, 30°, 60°, 90° — 30 seconds each, on a rotating turntable |
An IP69K connector isn't necessarily immersion-resistant too — that's a separate property. If a project needs both high-pressure washdown resistance and occasional submersion, check that the manufacturer publishes both ratings independently rather than assuming one from the other.
Side by side
| Rating | Standard | What it tests | Typical application |
|---|---|---|---|
| IP65 | IEC 60529 | Water jet, 30 kPa | Outdoor installations |
| IP67 | IEC 60529 | Immersion 1 m / 30 min | Occasional flooding |
| IP68 | IEC 60529 | Immersion per manufacturer | Permanent submersion |
| IP69K | ISO 20653 | Washdown 80–100 bar, 80°C | Industrial/food wash-down |
What CME carries today
CME distributes TTAF waterproof connectors: the TT20 / TT25 / TT30 / TT35 power series and the TT30 Data series (fiber, RJ45, USB, HDMI), all rated IP65/IP67, plus the M12 circular TT12 series and the panel-mount TTN series (RJ45, HDMI, USB, Type-C, VGA, fiber), rated IP67.
Full technical specifications, dimensions and product codes are in the manufacturer's catalogue. CME does not currently carry TTAF variants rated IP68 or IP69K — if your project needs one of those classes, get in touch and we'll check available alternatives.
What to send with your RFQ
- The operating environment: splash, rain, occasional flooding, permanent submersion, or pressure/steam washdown.
- If immersion applies — the required depth and duration, not just a target IP class.
- Operating temperature range and exposure to chemicals or cleaning agents.
- Connector type, pin count, rated current/voltage, and mounting style (panel vs. cable).
- Planned quantity, delivery schedule, and any required documentation.
Frequently asked questions
Does IP68 mean a connector stays waterproof underwater indefinitely?
No. IEC 60529 doesn't define one fixed depth or duration for IP68 — manufacturers set and publish those parameters themselves. Always check the actual tested conditions in the datasheet, not just the IP68 label.
Is an IP69K connector automatically also IP68?
Not always. These are two separate tests — high-pressure washdown (IP69K) and immersion (IP68) — and a product may only carry one of them. Many industrial connectors publish both ratings together, but that needs to be confirmed in the documentation, not assumed.
Which IP rating do I need for an industrial wash-down or food-processing line?
IP69K is the relevant test there (high pressure and temperature), not IP68 — immersion and jet washdown are different physical scenarios. If the equipment can also be submerged, you need both ratings confirmed separately.
See also the full CME waterproof connector category.